Align the design basis
Confirm home, room, envelope, design conditions and load outputs used by each proposal.
Proposal normalizer
Compare design basis, exact models and capacity, distribution, electrical, backup, controls, permits, commissioning and warranty evidence.
Decision file
Confirm home, room, envelope, design conditions and load outputs used by each proposal.
List indoor and outdoor models, ratings, relevant capacity data, matched combinations and substitutions.
Compare ducts, indoor units, zoning, registers, returns, line routes, penetrations, condensate and restoration.
List assessments, circuits, service work, outdoor base, drainage, snow, sound and backup integration.
Compare permits where applicable, thermostats, integration, monitoring and owner training.
Require start-up and test records, settings, airflow or refrigerant documentation as applicable, manuals and warranty evidence.
Give every proposer the same room record, design assumptions, envelope plans, distribution evidence, electrical context and backup goals. Record calculation or sizing differences explicitly before ranking price or equipment.
List outdoor and indoor model pairing, low-temperature capacity, controls, backup integration, ducts or heads, drains, line sets, electrical work and outdoor mounting. Require current performance tables and written substitution review.
Compare permits, access, protection, penetrations, finish repairs, removal, schedule milestones and change rules. Handover should include tests, airflow or commissioning records, controls training, filter access, manuals, warranties and incentive documents.
Give each proposer the same room record, load and design assumptions, envelope plans, distribution evidence, electrical context, backup goals and outdoor-location constraints. Compare exact equipment pairings and low-temperature data, ducts or heads, controls, drains, line sets, electrical and mounting, permits, removals, protection and finish repair. Record changes, alternatives and incentive responsibilities separately. Require commissioning, airflow or settings evidence, controls training, filter access, manuals and warranties at handover. The ledger prevents a nominal tonnage or rebate estimate from standing in for a complete house-specific system. Hold a proposal-leveling review using the house brief, and issue written answers for sizing, distribution, backup and outdoor-location differences. Incorporate those answers before equipment is ordered or an incentive application begins.
Primary references
Links checked in the approved research packet on August 26, 2026. Applicability still depends on the property and proposed scope.